Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN331
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Tailored
Payment Terms :T/T
Supply Ability :1 Set Per Month
Delivery Time :2 Months
Packaging Details :Plywood
UUT :Air Conditioners & Heat Pumps
Chamber External Size :10000mm W×5000mm D×3500mm H
Indoor Size :4500mm W×4000mm D×3200mm H
Outdoor Size :4000mm W×4000mm D×3200mm H
Outdoor Temperature :-10 ° C and up to 50 ° C
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

3HP Air Enthalpy Method Calorimeter Testing Laboratory for Air Conditioners and Heat Pumps

Overview:

The test laboratory can accurately measure the air conditioning cooling capacity, heating capacity, cooling power consumption, heating power consumption, EER, COP, and inverter air conditioner’s rated / maximum / intermediate / minimum cooling capacity, rated / low temperature / intermediate / heating, cooling and heating power consumption, EER, COP, SEER and APF, etc.

The test laboratory can test 1~3PH household air conditioners. The test models cover all types of window, split wall mount, split cabinet and split ceiling cassette.

The test laboratory uses the air enthalpy method to measure the amount of cooling and heating capacity generated by the measured unit. The laboratory is divided into indoor and outdoor rooms. The indoor room mainly simulates the indoor working condition environment, and the outdoor room mainly simulates the outdoor working condition environment. The outdoor side temperature can be as low as -10 ° C and up to 50 ° C. Can meet the performance testing requirements of household air conditioning.

Standards:

Design and Testing according to the following standards:

► ISO 5151:2010

► ISO 16358:2013

► Other standards can be customized

Types of UUT :

- Split wall type

- Split cabinet type

- Split ceiling cassette type

- Window type

- Inverter air conditioner

Testing Range:

Test range

Cooling capacity

(W)

Heating capacity

(W)

Input power

(W)

Air Flow

(m³/h)

≤7500 ≤9000 ≤8000 200~2000

Indoor Size Dry bulb Temperature Indoor Size Wet bulb Temperature Outdoor Size Dry bulb Temperature Outdoor Size Wet bulb Temperature Power
Control Range 0~50℃ 0~50℃ -10~55℃ 0~55℃(Relative humidity control below 0°C,0~95%RH) 0~8KW
Control Accuracy ±0.2 ±0.2 ±0.2 ±0.2 ±0.5%
Display Accuracy ±0.1 ±0.1 ±0.1 ±0.1 ±0.1%

Technical Indicators:

Working conditions Indoor side air return condition of /℃ Outdoor side air inlet condition of /℃
Dry bulb temperature Wet bulb temperature Dry bulb temperature Wet bulb temperature
Cooling operation Rated cooling T1 27 19 35 24
T2 21 15 27 19
T3 29 19 46 24
Maximum cooling T1 32 23 43 26
T2 27 19 35 24
T3 32 23 52 31
Freeze-up T1 21 15 21 -
T2 10 -
T3 21 -
Minimum cooling 21 15 Minimum temperature recommended by the manufacturer

Condensation

Condensate removal

27 24 27 24
Heating operation Heat pump rated heating High temperature 20 15(Max.) 7 6
Low temperature 2 1
Extra-low temperature -7 -8
Maximum heating operation 27 - 24 18
Minimum heating operation 20 - -5 -6
Automatic defrost 20 12 2 1
Electric heating rated heating 20 - - -