Add to Cart
IEC 60335-1 Oxygen Bomb (Air Bomb) Aging Test Chamber
Standards & Clauses:
IEC60335-1:2016 “Household and similar electrical appliances-Safety-Part1:General requirements” clause 22.32
Samples and Restrictions:
Wire and cable, rubber (plastic, leather) insulation and sheathing, as well as other polymer material
Application:
It is suitable for the aging test in the oxygen and compressed air to the wire and cable, rubber (plastic, leather) insulation and sheathing, as well as other polymer materials under the action of a predetermined pressure and temperature.
Equipment Structure:
The test device is composed of stainless steel tank container, electrical control cabinet.
The tank consists of outside enclosure, insulation layer, heater, temperature aluminum cover, stainless steel pressure tank, the sample tray, automatic overpressure protection devices and other components.
The electrical control cabinet mainly consists of outside cabinet, power distribution box and gas distribution chassis.
Technical Parameters:
Parameters Name | Parameter Data |
Power | AC 220V±10%, 50Hz or match client's local power supply |
Maximum Working Pressure | 4MP/C㎡ |
Security Burst Pressure | 2.7-3.3MP/C㎡ |
Temperature self-control range | Room temperature -200℃ |
Temperature Deviation | ±1℃ |
Temperature control | Digital display automatic control |
Tank materials | Stainless steel |
Tank volume | 4000cm3 |
Heater power | 2.4KW |
Dimensions | 820×420×670mm |