Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Electrical Appliance Testing Equipment /

Cordless Kettle Dry Heating Boiling Insertion Withdrawn Automatic Test System 6 Stations

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

Cordless Kettle Dry Heating Boiling Insertion Withdrawn Automatic Test System 6 Stations

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN1119B-6
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Customized
Payment Terms :T/T, L/C, D/A, Western Union, MoneyGram
Supply Ability :10 Sets Per Months
Delivery Time :1 Month
Packaging Details :Plywood
Work Station :6 Stations
Control Method :Mitsubishi PLC
Load Voltage :0-280V adjustable
Load Current :0-20A adjustable
Test Cycles :0~999999 adjustable
Test Time :0-999.9s adjustable
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Automatic Cordless Kettle Abnormal Operation Stress Withstand Safety Test System

Overview:

This integrated test equipment confirms to IEC60335-2-15 clause 19.3, 19.101, 19.102 and clause 22.103 standard requirements. It is used for the kettles’ dry heating test, water boiling test and insertion & withdraw with or without current test, it can be widely used in production line detection and laboratory measurement.

It aims at eliminating the fire dangerous caused by the designing of the electric circuit in abnormal work or wrong operation, so as to avoid mechanical properties damages due to electrical safety or anti-shock protection is damaged.

Testing Functions:

A. Water boiling test under constant voltage at 0.85 and 1.24 times rated power.

B. The water boiling test when the water injection is over heating elements (inside the kettle) or 10mm deep (the heating element is outside of the kettle).

C. The drying heating test (no water test, thermal circuit breaker does not work, short circuit) under constant voltage of 0.85 and 1.15 times rated power, with 2 reset circuit breakers, one of which is short circuit.

D. Drying test by 0.85 or 1.15 times rated power, inject water of 15±5°C for water cooling when the circuit breaker works within 2s. The water inside of the kettle is poured out after 1min, this test will be carried out for 100 times.

E. The pin of the cordless kettle is in series connection, external resistive load is in series connection with power supply, the circuit will generate times rated current under rated voltage, the kettle will do the insertion & withdraw test by a speed of 10 times/min, process load test for 10000 times, non-load test for 10000 times, the kettle can be in normal use after test. The purpose is to verify the electrical and mechanical damages to the structure of the kettle base which are generated during normal use will not cause dangerous.

Techinal Parameters:

S/N. Item Parameters
1 Control Mitsubishi PLC
2 Display Touch screen
3 Speed Controlled by cylinder, can be adjusted by regulating throttle
4 Test times 0~999999, can be preset
5 Test Time 0-999.9s, can be preset
6 Fixture Can be applied to a variety of samples
7 Load current and voltage

0-250V, 0-16A, adjustable

Can be customized

8 Load and non-load test Can be automatically switched
9 Test station

6 stations, each station can work independently, without disturbing each other

( workstations can be customized)

10 Air pressure 0.5-0.6Mpa, the air compressor needs to be equipped by user
11 Power supply Match client's local power supply requirements
Integrated fixture and auxiliary buttons, which can be applied to various types of samples
Inquiry Cart 0