Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Switch Life Tester /

Conductors Undue Damage Checking Test Apparatus 10±2 RPM IEC 60884-1 Figure 11

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

Conductors Undue Damage Checking Test Apparatus 10±2 RPM IEC 60884-1 Figure 11

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN2111
Certification :Calibration Certificate(cost additional )
Place of Origin :China
MOQ :1 Set
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :20 Sets / Month
Delivery Time :30 days
Packaging Details :Standard Exporting Plywood Case
Standard :IEC60884 Clause 12.2.5, Figure 11
Test sample :Terminals with Screw Clamping
Rotate Rate :10±2 RPM
Test Height :260, 280, 300, 320mm
Gyration Diameter :75mm
Bushing Diameter :6.5, 9.5, 13, 14.5mm
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60884-1 Figure 11 Conductors Undue Damage Checking Test Apparatus

Standard: IEC60884-1 clause 12.2.5, figure 11.

Application: It is used to check terminals with screw clamping shall be so designed and constructed that they clamp the conductor(s) without undue damage to the conductor(s).

Test sample: Plugs and socket-outlets terminals.

Technical Parameters:

Model SN2111
Test rate 10±2 RPM
Diameter of gyration 75mm
Test times 0~9999
Test weights 0.3, 0.4, 0.7, 0.9, 1.4, 2kg
Test height 260, 280, 300, 320mm
Diameter of bushing 6.5, 9.5, 13, 14.5mm
Complied standards IEC60884-1, IEC60669-1

Test processes:

The terminal is placed in the test apparatus according to figure 11 and fitted with rigid, solid, stranded and/or flexible conductor(s), according to table 3 first with the smallest and then with the largest nominal cross-sectional area, the clamping screw(s) or nut(s) being tightened with the torque according to table 6.

Where rigid stranded conductors do not exist, the test may be made with rigid solid conductors only. In this case, there is no need for further tests.
The length of the test conductor shall be 75 mm longer than the height (H) specified in table 9.
The end of the conductor is passed through an appropriate bushing in a plate positioned at a height (H) below the equipment, as given in table 9. The bushing is positioned in a horizontal plane such that its centre line describes a circle of 75 mm diameter, concentric with the centre of the clamping unit in the horizontal plane; the platen is then rotated at a rate of (10 ± 2) r/min.
The distance between the mouth of the clamping unit and the upper surface of the bushing shall be within ±15 mm of the height specified in table 9. The bushing may be lubricated to prevent binding, twisting, or rotation of the insulated conductor.
A mass as specified in table 9 is suspended from the end of the conductor. The duration of the test is approximately 15 min.
During the test, the conductor shall neither slip out of the clamping unit nor break near the clamping unit, nor shall the conductor be damaged in such a way as to render it unfit for further use.

Comparison table of the weight, height and bushing as below:

Nominal cross-sectional area of conductor ( mm²)

Diameter of bushing Hole

( mm)

Height (mm) Mass for conductor (kg)
0.5 6.5 260 0.3
0.75 6.5 260 0.4
1.0 6.5 260 0.4
1.5 6.5 260 0.4
2.5 9.5 280 0.7
4.0 9.5 280 0.9
6.0 9.5 280 1.4
10.0 9.5 280 2.0
16.0 13.0 300 2.9
  1. The Corresponding size with mm² see IEC 60999-1.
  2. The height:±15mm.
  3. If the bushing-hole diameter is not large enough, you can choose the larger one.
  4. 2.9Kg weights are composed of 2Kg weights and 0.9Kg weights
Inquiry Cart 0