Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Switch Life Tester /

Plug Socket - Outlet 100N Test Device For Testing Non - Solid Pins IEC 60884-1 Figure 14

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

Plug Socket - Outlet 100N Test Device For Testing Non - Solid Pins IEC 60884-1 Figure 14

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN2114
Certification :Calibration Certificate(cost additional )
Place of Origin :China
MOQ :1 Set
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :100 Sets / Month
Delivery Time :15 days
Packaging Details :Carton Box
Standard Clause :IEC60884 Clause 14.2
Test Sample :Plug pins
Load Weight :100N
Steel Rod :Φ4.8mm
Test Time :1 minute
Frame Material :Stainless steel
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60884-1 Clause 14.2 Figure 14 Device for Testing Non-Solid Pins

Product information:

The appliance is checked by the test of IEC60884-1 clause 14.2, figure 14, for checking pins which are not solid whether can withstand the sufficient hardness.

Technical parameters:

No.: Specifications
Load weight 100N
Steel rod Φ4.8mm
Time for force application 1 minute
Equipment material Stainless steel

Test process:

1. When using the instrument for the first time, horizontal position adjustment is needed, first place the tester in a horizontal table, and adjust the four feet of the tester, until the horizontal bubble is in the center position.

2. A force of 100 N is exerted on the pin, which is supported as shown in figure 14, last 1 min in a direction perpendicular to the axis of the pin, the force is applied by theΦ4.8 mm steel rod, the axis of which is also perpendicular to the axis of the pin.

3. During the application of the force, the reduction of the dimension of the pin at the point where the force is applied shall not exceed 0.15 mm.

4. After removal of the rod, the dimensions of the pin shall not have changed by more than 0.06 mm in any direction,

5. The equipments should be cleaned and maintained after completing the test.

Inquiry Cart 0