Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Switch Life Tester /

1 Or 3 Stations Switch Life Tester IEC 60884-1 Figure 27 And 42 Power Cables Low Temperature Impact Test Apparatus

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

1 Or 3 Stations Switch Life Tester IEC 60884-1 Figure 27 And 42 Power Cables Low Temperature Impact Test Apparatus

Ask Latest Price
Brand Name :Sinuo
Model Number :SN2127
Certification :Calibration Certificate(cost additional )
Place of Origin :China
MOQ :1 Set
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :10 Sets / Month
Delivery Time :30 days
Packaging Details :Standard Exporting Plywood Case
Standard Clause :IEC60884 Clause 24.4, 30.4
Test Figure :Figure 27 and 42
Test Stations :1 or 3
Impact Height :100mm
Steel Intermediate Piece :Φ20mm
Impact Hammer Weight :1000±2g and 100±1g
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60884-1 Figure 27 and 42 Low Temperature Impact Test Apparatus

Product information:

The low temperature impact test apparatus meets the requirements of IEC 60884-1 2013 clause 24.4, 30.4, figure 27 and 42, IEC60811-1-4, VDE0620 and so on. This device is used to check the impact resistance at low temperature of electrical accessories, as well as wires and cables.

Equipment characteristics:

This device should be used with low temperature chamber, the device should be placed on the sponge rubber pad of about 40mm thick, and should be put in the low temperature chamber before and during the test.

Technical parameters:

Model SN2127 SN2127A
Station Single station Three stations
Weight of the impact hammer (g) 1000±2 and 100±1 100, 200, 300, 400, 500, 600, 750, 1000, 1250, 1500(See table 1 and 2)
Height of the impact (mm) 100 100
Steel intermediate piece Φ20, bottom end rounded R300, 100g Φ20, bottom end rounded R300, 100g
Applied Standard

IEC60884-1 24.4 Figure 27

IEC60884-1 30.4 Figure 42

IEC60811-1-4
Operation Manual, mechanical release Manual, mechanical release

Table1 For power cables for fixed installation, the mass of the hammer for testing the samples shall be as given in the following table:

Overall diameter (mm) Mass of hammer (g)
Above Up to and including
- 4.0 100
4.0 6.0 200
6.0 9.0 300
9.0 12.5 400
12.5 20.0 500
20.0 30.0 750
30.0 50.0 1000
50.0 75.0 1250
75.0 - 1500

Table 2 For flexible cables and cords and telecommunication cables, the mass of the hammer for testing the sample shall be as follows:

Overall diameter (mm) Mass of hammer (g)
Above Up to and including
For flat cords 100
- 6.0 100
6.0 10.0 200
10.0 15.0 300
15.0 25.0 400
25.0 35.0 500
35.0 - 600
Inquiry Cart 0