Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Switch Life Tester /

UL 60335-2-24 Figure 101.DVA.2 Articulate Probes 10.5-11.5 Year Age

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

UL 60335-2-24 Figure 101.DVA.2 Articulate Probes 10.5-11.5 Year Age

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN2210-50
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Customized
Payment Terms :L/C, , T/T, Western Union, MoneyGram
Supply Ability :50 sets per month
Delivery Time :15 Days
Packaging Details :Plastic Case
Applied Standard :UL 60335-2-24
Applied Figure :Figure 101.DVA.2
Probe Material :Stainless steel
Handle Material :Nylon
Applied Force :Should work with force gauge
Applied Age :10.5-11.5 year age
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

UL 60335-2-24 Figure 101.DVA.2 Articulate Probes 10.5-11.5 Year Age

Product Overview:

This articulate probe meets the requirements of UL 60335-2-24 figure 101.DVA.2. It is used for hazard assessment for moving parts of refrigeration or similar products, the moving parts should not cause personal injury when touched by children between 10.5 and 11.5 years old.

The test probe is made of stainless steel with nylon handle, it is manufactured according to the standard figure.

The force is achieved by working with a force gauge, there is a M6 thread hole on the handle of probe which can match a force gauge.

Application:

When evaluating potential pinch points, the probes of Figure 12DV, of the Part 1, Figure 101.DVA.1 and Figure 101.DVA.2 cannot penetrate the opening, or the maximum force exerted by the moving part onto the probe is less than 22.2 N (5 lbf) at any location ACCESSIBLE by the probe.

Probe Dimension:

Item Dimension Description

Dimension

mm

A Middle finger length, 95 percentile 77
B Middle finger diameter, 5 percentile 11.4
C Hand Length, 95 percentile 173
D Elbow to wrist length, 95 percentile 235
E Wrist diameter (circumference divided by pi), 5 percentile 37
F Forearm diameter (circumference divided by pi), 5 percentile 57
G Minimum hand CLEARANCE (cone shaped hand part) , 5 percentile 49.4
H Cone shaped part at finger attachment 25
I Hand breadth (flat hand part), 5 percentile 62
J Wrist breadth (used for the hand thickness-flat hand part) , 5 percentile 29
K Hand breadth at finger attachment (flat hand part) 46
L Upper arm length, 95 percentile a

Notes:

1-The probes were designed with a center pin to rotate the hand with respect to the lower arm. That motion can be equivalently represented by rotating the probe.

2-The finger “tip” is developed to match the dimensions of the UL articulated probe. The diameter from the tip to the first joint them tapers from the tip dimensions to the finger diameter. The joints are spaced equally along the finger length.

3- The probe is designed to permit the hand to “bend” with respect to the arm using a hinge pin located 6mm (0.24 in) from the hand length (wrist end) and the hand is restricted in bending not more than 90° with respect to the arm.

a If the upper arm is required to evaluate a part it shall consist of a flexible tube attached at the end of the lower arm, as the exact position of the elbow cannot be readily determined from the data points chosen.



Inquiry Cart 0