10/700 µs Impulse Voltage Test Generator Transient Voltages Tester

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN1104-2
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :L/C, T/T, Western Union, MoneyGram
Supply Ability :50 sets per month
Delivery Time :20 Days
Packaging Details :Carton Box
Output Voltage :6kV (Max)
Internal resistance :40Ω or 500Ω
Impulse Wavefront Time :10 µs ± 30 %
Half Value of after Wave Time :700 µs ± 20 %
Peak Voltage Range :0kV~6kV
Impact Interval Time :30~999s
Impact Cycles :1 ~ 9999
Applied Standard :IEC 60335-1, IEC 60065, etc.
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60065 6KV 10/700 μs Impulse Voltage Test Generator

Product information:

This impulse voltage test generator is required by IEC60065:2014 clause 10.2, 13.3.4 a), and IEC 60065:2014 clause 13.3.4 b), 14.2, IEC60950, and etc.

It is used to detect the transient over voltage of the components and the electrical clearance and the creepage distance of audio, video and similar electronic apparatus.

This impulse voltage test generator is a standard lightning wave test device with waveform 10/700 µs. Wavefront time is 10 µs, wave after time is 700 µs, it is a destructive tester. The sample breakdown will produce a spark and acoustic, instrument peak voltage than the no-load voltage is decreased substantially (close to zero), when applying the same voltage in the next test, it will also show the above phenomenon.

Technical Parameters:

Model SN1104-2
DC high voltage 6kV
Impulse voltage wave Impulse wavefront time: 10 µs ± 30 %

Half value of after wave time: 700 µs ± 20 %

Note: the waveform will be shown by an external oscilloscope (oscilloscope should be prepared by user).

Instrument internal resistance 40Ω ± 10%
Internal resistance converter box 500Ω - 10% , optional
Peak voltage: 300 V~ 12,500V 0kV~6kV, ± 5%
Impact interval time 30~999s
Impact cycles 1 ~ 9999
Polarity Positive and negative
Working power source Match client’s local power supply requirements
Dimension 630mm×600mm×380mm
Weight 30 KG

Equipment features:

All parameters can be set on the touch screen. After the sample is connected, click "Start Test" to start the test.
The test interface as shown in the figure below, and the high-voltage warning light flashes intermittently, indicating that the test is in progress. After the test is completed, it will stop automatically.

Inquiry Cart 0