Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Flammability Test Chamber /

IEC 60112 CTI PTI Tracking Flammability Test Chamber PLC Control

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

IEC 60112 CTI PTI Tracking Flammability Test Chamber PLC Control

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN774
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :T/T, L/C, Western Union, MoneyGram
Supply Ability :10 Sets Per Month
Delivery Time :30 Days
Packaging Details :Plywood
Applied Standard :IEC 60112
Control :Integrated PLC
Display :7" touch screen
Test Voltage :0~600V adjustable
Electrode Material :Platinum electrodes and brass electrodes
Electrode Pressure :1.00N±0.05N
Dropping Liquid Height :35±5mm
Dropping Liquid Volume :45~50 drip/cm3
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60112 Leakage Tracking Test Apparatus

Product overview:

The leakage tracking test equipment is designed and manufactured according to the standard requirements of IEC60112, it is required by IEC60335-1 clause 29.2 and Annex N, IEC 60065:2014 clause 13.4, IEC60598-1, IEC 60884-1, UL746A and ASTM D3638-92 and etc. It is used for determination of the relative resistance to tracking performance that solid electrical insulating material under the action of an electric field, when the surface exposed to water containing impurities.

The leakage tracking tester adopts to advanced PLC control system and humanized 7” color touch screen, the dripping is controlled by a high-precision micro water supply pump, the timing is automatic, the electrode pressure sensor is accurate, and the operation is simple, accuracy is high, it is leading among similar equipment.

Technical parameters:

Parameter model SN774 (0.5m³)
Working voltage Match client's local power supply requirements
Control Advanced PLC
Display 7 inch color touch screen
Testing voltage 0~600V adjustable, precision 1.5%
Timing device 9999X0.1S
Electrode Platinum electrodes and brass electrodes, each of a pair
Electrode dimension

(5±0.1)×(2±0.1)×(≥12),

30°slant

Electrode included angle and distance 60°±5°, distance is (4±0.1) mm
Electrode pressure 1.00N±0.05N
The interval of dropping liquid 30±5S, adjustable
Dropping liquid height 35±5mm
Dropping liquid delay 0.2S(solenoid valve opening time)
Dropping liquid volume 45~50 drip/cm3
Time-delay circuit 2±0.1S (in 0.5A or larger current)
Short-circuit pressure drop 8% MAX
Short-circuit current

1±0.1A

Accuracy: 1%

Wind speed 0.2m/s
Environmental requirement 0~40℃, relative humidity≤80%, in the place of no obvious vibration and corrosive gas
Equipment size & weight 1100mm* 620mm* 1450mm, 180KGS
conforms to standard IEC60695, IEC60112, IEC 60598-1, IEC 60884-1, UL746A, ASTMD3638, etc.