Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Switch Life Tester /

IEC 60884-1 Screwless Terminals Deflection Test Apparatus 100A

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

IEC 60884-1 Screwless Terminals Deflection Test Apparatus 100A

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN2112
Certification :Calibration Certificate(cost additional )
Place of Origin :China
MOQ :1 Set
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :20 Sets / Month
Delivery Time :30 days
Packaging Details :Standard Exporting Plywood Case
Test Sample :Screwless Terminals
Test Content :Deflection and voltage drop
Deflection Angle :0-360°
Deflection Force :0.25N, 0.5N, 1.0N
Deflection Direction :12 directions
Test Current :Max. 100A
Standard & Clause :IEC60884 Clause 12.3.12
Standard Figure :Figure 12
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60884-1 Screwless Terminals Deflection Test Apparatus

This device complies with IEC 60884-1:2013 clause 12.3.12 and figure 12, it is used to use to check whether the screwless terminals connected rigid solid conductor remains clamped, even when it has been deflected during normal installation. Deflecting the conductor and measuring the voltage drop, to check the screwless terminal clamping capacity and contacting performance.

The device is easy for operating, the load current is adjustable, the sample fixture is manufactured according to the standard requirements.

Technical Parameters:

Parameters Name Parameter Data
Deflection angle

0-360°

(there is an angle indicator in the device)

Deflection direction

In any of the 12 directions differing from each other by 30°±3°

(manually deflected)

Deflection force 0.25N, 0.5N, 1.0N
Force applied direction Perpendicular to the undeflected conductor
Test current Max.100A
Accessories Voltage input clamps and current output clamps
Power supply Match client's local power supply requirements
Sample installation:
1. Two insulation layer peeled solid conductors (about 150 mm) are separately inserted into both ends of the screwless terminals.

2. Placed the screwless terminals into the fixture, the perpendicular of the conductor should be coincided with the center of the base. The upper conductor passes through the holes of the force plate, the lower conductor should not touch the floor , then clamp the terminal parts.
3. Loose the fastening handle of the support column and move the crossbar up and down, so that the distance from the end of the terminal to the force plate is 100 mm. The crossbar must be kept horizontal.

4. The red clip of the current output of the voltage drop tester is clamped on the upper conductor, and the red clip of the voltage drop measurement input is clamped in the position near the terminal, then hang on the weight.

5. clamped on the lower conductor, and the black clip of the voltage drop measurement input is clamped in the position near the terminal.

6. Rotate the base turntable, each rotation is 30 °, the starting point should be where the conductor in a natural state.