Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Vehicle Testing Equipment /

IEC 62196-1 Programmable Temperature Rising Test System 1000A

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

IEC 62196-1 Programmable Temperature Rising Test System 1000A

Ask Latest Price
Brand Name :Sinuo
Model Number :SN1106-500A/SN1106-1000A
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Customized
Payment Terms :L/C, , T/T, Western Union, MoneyGram
Supply Ability :1 set per month
Delivery Time :45 Days
Packaging Details :Plywood
Applied Standard :IEC 62196-1: 2020
Applied Figure :Fig A 109, C 109, D 109
Output Current :500A or 1000A
Output Voltage :Max. DC5V
Test Current Stability :± (1% set value + 5 words)
Current Display Accuracy :± (0.5% reading + 0.5% range)
Temperature Measurement Points :16 channels
Temperature Measuring Range :0~260℃
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 62196-3-1 Programmable Temperature Rising Test System 1000A

Product overview:
This temperature rising test system meets the test requirements of IEC 62196-1: 2020 clause 24, IEC 60309-1: 2012 clause 22, , IEC60309, IEC60998, IEC60669, IEC61058, IEC60439EC60309, IEC60998, IEC60669, IEC61058, IEC60439, etc. It can be used to assess the surface heating conditions of electrical accessories when electrical accessories are connected to the load current, and whether the electrode temperature rise meets the requirements of the standard.

Technical parameters:
1. Computer program control to set DC current source:
Maximum output voltage: DC5V
Output constant and adjustable test current: DC1~50~500A two gears continuously selectable or DC 10~1000.0A can be customized
Test current stability: ± (1% set value + 5 words), response time 1S
Current display accuracy: ± (0.5% reading + 0.5% range)
Impedance voltage display accuracy: ± (0.3% reading + 5 words)
2. Working mode: continuous mode, on-off mode, automatic temperature control mode
Continuous on-off mode:
Continuous mode test time: 0.01~99.99 hours
Power-on/power-off time in on-off mode: 0.01~99.99 hours
On-off times: 1~9999 times, the machine will stop automatically when the times are reached
Current setting: computer program control setting
3. Automatic temperature control mode: you can set a stable temperature and automatically find the appropriate current value
Automatically obtain the current result that requires the temperature rise value

Temperature measurement:
Multi-channel temperature tester

Measuring range 0~260℃, accuracy 0.3% of reading+1℃; resolution: 0.1℃
Temperature measurement points 16 channels (including 1 point to measure the ambient temperature)
Temperature scanning speed 1~255 seconds for all channels
Temperature data recording

Completed by computer, equipped with computer test software
The software can set the ambient temperature channel, and the ambient temperature can be automatically subtracted when collecting data

Temperature measuring thermocouple American Ω company J type 30AWG filament thermocouple, length 2 meters, a total of 16 pieces
The temperature probe It can be charged with AC300V for testing without damaging the instrument
Thermocouple accuracy Class I
Thermocouple test temperature range -50~260℃
Temperature data recording It is automatically completed by the computer, equipped with computer testing softwre, and can export Excel reports.


Computer Configuration:
CPU1.8G, 4G memory, 128G hard disk, windows7 operating system and OFFICE processing software
With RS232 communication interface
Automatically record the temperature change curve, can query, print, and export data
Software function:

A. Different working modes can be set: continuous mode, on-off mode, temperature control mode
B. Current program control settings
C. Automatically record data and draw curves: temperature rise-time curve, current-time curve, temperature rise-current curve, data export and other functions

Inquiry Cart 0