Add to Cart
IEC 62368-1Clause Annex S Horizontal And Vertical Burning Test Apparatus
Product Information:
This test apparatus is designed and manufactured according to the standard requirements of IEC 62368-1:2018 Annex S, IEC 60950:2013 clause 4.7.3, IEC60065:2014 clause 14.1, 20.2.1, 20.2.4, Annex G, IEC60335-1 clause 30, etc. It simulates the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. It is mainly used in plastic and other non-metallic material sample, solid material. It is also applicable in the Horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is no-less than 250kg/m according to ISO845 test method. It is also applicable in the Horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is no-less than 250kg/m according to ISO845 test method.
This series of products adopt integral type inlet ignition system. The combustion time delays 0.1S thus to make sure the sufficient time of gas burning. They are with matte black background, multi-functional flame measure gauge, stainless steel of box full, large observation window, imported digital indicator of high precision, nice appearance. And they gather a number of advantages of similar products home and abroad.
Technical Parameters:
Applied standard | IEC 62368-1 |
Clause | Annex S |
Working voltage | 220V/50Hz |
Power/grade | 50W and 500W double power switching |
Control operation mode | PLC control, 7-inch color touch screen operation, with infrared remote controller |
Blast burner standard | IEC60695-11-3/IEC60695-11-4/10, UL94, etc. |
Gas pressure | 0.1MPa |
Gas flow | 50W:105±5ml/min or 18±1mm;500W:965±30ml/min or 117±3 mm,flow meter adjustment |
U type pressure gauge back pressure water column height | 50W:10mm; |
Test angle | 50W: 0°,45°; |
Burning time | 0-9999X0.1S Can be preset |
Burning times | 0-9999 times,Can be preset |
Residual flame/Residual glow | 0-9999X0.1S Can be displayed |
Test flame calibration | Temperature measuring copper head:50W:Ф5.5mm±0.01mm,weight before drilling 1.76 ± 0 .01 g;500W:Ф9mm±0.01mm,weight before drilling 10 ± 0 .05g |
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100° | |
Distance between the bunsen burner port to temperature measuring copper block:50W: 10±1 mm; 500W: 55±1 mm | |
Flame height:50W: 20±2mm(there is no internal and external flame); 500W: Inner flame:40±2mm,Outer flame:125±10mm | |
Temperature rise time from100±2°to 700°±3°50W: 44±2S; 500W: 54±2S | |
Lighting | Equip with lighting in the test chamber, with control |
Test chamber and dimension | > 0.75 cube, black inwall, with exhaust fan, dimension:1100*550*1200mm, 140kg |