Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Switch Life Tester /

IEC60068-2-75 Environmental Testing Required Calibration Device For Spring Hammer

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

IEC60068-2-75 Environmental Testing Required Calibration Device For Spring Hammer

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN2208
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :T/T
Supply Ability :20 Sets Per Month
Delivery Time :15 Days
Packaging Details :Standard Exporting Boxed
Applied Standard :IEC60068-2-75 and etc.
Minimum Scale :0.01J
Repeat Accuracy :±0.01J
Test Range :0-2J,Maximum measurable 2J
Outer Dimeter of Guide Groove :51mm
Pendulum Energy Loss :<0.002j
Warranty Time :One year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC60068-2-75 Environmental Testing Required Calibration Device For Spring Hammer

Product Information:

The Calibration Device for Spring Hammer Test Apparatus is designed and manufactured according to the standard requirements of IEC60068-2-75:1997 Annex B, IEC60068-2-63:1997 Annex A, and etc.

The device is used to detect the impact energy of the Spiring Hammer Tester.

When the spring hammer is released, it impacts on the pendulum rod on the calibration device, and the pendulum rod drives the pointer to the highest position of the pendulum rod, which is the energy of the spring impactor. Check the position indicated by the pointer to record the impact energy value.

Technical Parameters:

Minimum Scale 0.01J
Repeat Accuracy ±0.01J
Range 0-2J, Maximum measurable 2J
Outer Dimeter of Guide Groove 51mm
Pendulum Energy Loss <0.002j
Trigger Stroke >30mm
Weight Copper weight set 1piece(2J)


Operation steps

  1. Adjust the 4 feet of the calibration device, the horizontal bubble is in the center position, so that the calibration device is in a horizontal state.
  2. Choose a copper sleeve and a release fixture according to the energy of the impact. The 2J impact hammer needs to be covered with a copper weight cover, and the opening of the release fixture is wide; the impact hammer below 2J needs to remove the copper weight cover, and choose to release clamp opening narrow.
  3. Turn the handwheel to move the base back, load the spring impact hammer, and place it on the seat.
  4. Keep the pendulum in a vertical state without shaking, and move the pointer to the 0-scale position.
  5. Manually rotate the handwheel to move the spring impact hammer forward. When it moves to the spring impact hammer release fixture, the spring impact hammer is released, and the hammer head hits the pendulum rod to drive the pointer to rotate. When the pendulum rod is turned back, hold the pendulum rod with your hand to prevent the pendulum rod from hitting the spring impact hammer back.
  6. Read out the scale corresponding to the pointer to see if it is consistent with the marking of the spring impact hammer, repeat 3 times to ensure the accuracy.

Configuration

No.: Name Unit Quantity Remark
1 Main device Calibration Device for Spring Hammer Tester Set 1
2 Accessories Copper Weight Cover PC 1
Release Clamp PC 1
3 Document User manual Copy 1
Certificate of quality Copy 1
Warranty card Copy 1
Inquiry Cart 0