IEC 61032 Figure 2 Jointed Probe For Equipment And Persons Enclosures Protect

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN2210-2
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :T/T
Supply Ability :60 Sets Per Month
Delivery Time :3~5 Days
Packaging Details :Carton Box
Applied Standard :IEC 61032 and etc.
Applied Figure :Figure 2
Baffle Material :Nylon
Probe Material :Stainless steel
Force :Can be customized
Accessory :M6 thread and banana clip
Warranty Time :One year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 61032 Figure 2 Jointed Probe For Equipment And Persons Enclosures Protect

Product information:

The joint test probe of figure V.2 is in accordance with many standards like IEC 61032 figure 2, required by IEC 62368-1:2018 clause 5.3.2, 8.5.4.3, V.1.2 and figure V.2, IEC60884-1:2013 clause 10.1, 16.2, IEC 60669-1: 2017 Clause 10.1 &13.3.3 &20.1 &21.1, etc.

Techincal Parameters:

1. The dimensions are made according to IEC 61032 figure 2.

2. The finger probe material: stainless steel.

3. The baffle and handle material: nylon.

4. The end of the handle with a M6 thread hole, which is used for connecting with a force gauge to achieve required force value.

5. It is equipped with a cable, which is used for connecting with anti-shock probe experiment device to verify whether the appliance’s enclosure against electric shock.

Parameters /Model SN2210-2

SN2210-2A

(Optional)

SN2210-2B

(Optional)

SN2210-2T

(Optional)

Applied Standard

IEC 62368-1

figure V.2

IEC60335-1 IEC60335-2-14 IEC60529
Name Standard test finger Circular baffle test finger Large baffle test finger Standard test finger with force
1 30±0.2 30±0.2 30±0.2 30±0.2
2 60±0.2 60±0.2 60±0.2 60±0.2
3 80±0.2 80±0.2 100±0.2 80±0.2
4 180±0.2 180±0.2 ---- 180±0.2
5 R2±0.05 R2±0.05 R2±0.05 R2±0.05
6 S4±0.05 S4±0.05 S4±0.05 S4±0.05
7 37o 0 -10’ 37o 0 -10’ 37o 0 -10’ 37o 0 -10’
8 14 o 0 -10’ 14 o 0 -10’ 14 o 0 -10’ 14 o 0 -10’
9 Ф12 0 -0.05 Ф12 0 -0.05 Ф12 0 -0.05 Ф12 0 -0.05
10 Ф50 Ф50 ---- Ф50
11 20±0.2 ---- ---- 20±0.2
12 Ф75±0.2 Ф75±0.2 Ф125±0.2 Ф75±0.2
13 5±0.5 5±0.5 ---- 5±0.5
14 ---- ---- ---- 10-30N force

Operation steps

1. The test finger probe B joint part cannot be touched with the live parts, or cannot be close to the dangerous parts, and the 50mm-20mm baffle cannot enter.

2. The test of preventing from dangerous parts requires the test probe B with 10N±3N thrust. Generally, it needs to work with a force gauge. Please insert the force gauge connector into the M6 thread hole on the end of the handle.

3. For verifying whether LIVE PARTS touched, it requires working with an anti-shock probe experiment device: it is connected to the anti-shock probe experiment device (40V-50V), then operator processes the test according to the relative standard, the buzzer rings means electric shock prompted. Please refer to following pictures:

Notice

1. Please do not damage the appliance shape (such as scratching, bending, etc.).

2. Prevented from dust and moisture environment, in order to avoid the oxidation to affect the dimensional accuracy.

3. Be careful of electric shock.