Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Electrical Appliance Testing Equipment /

IEC60335-2 Probe With Thermometer For Surface Temperature Test

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

IEC60335-2 Probe With Thermometer For Surface Temperature Test

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN2210-32
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :T/T
Supply Ability :100 Sets Per Month
Delivery Time :5 Days
Packaging Details :Standard Exporting Box
Standard :IEC60335-2-6 Clause 11.101
Copper :Φ5*0.5mm
Thermocouple :K type, Φ0.3mm
Pull force :4±1N, Scale display
Handle :Nylon
Configuration :Thermometer
Brand name :Sinuo
Warranty time :One year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC60335-2 Probe With Thermometer For Surface Temperature Test

Product overview:

This probe conforms to the IEC 60335-2-11 Clause 11.3 Figure 101, IEC60335-2-6-2002 clause 11.101 figure 104, etc. It is mainly used to measure the temperature rise on the front surface of the easily accessible parts of drum-type dryer, upright electric cooker, cooking bench and oven.

Technical parameters:

Item Name Surface Temperature Probe
Measuring surface Φ5×0.5mm; Tinned copper disc
Polycarbonate tube Inside diameter: Φ3mm; outside diameter: Φ5mm
Thermocouple Φ0.3mm K type
Contact force 4±0.5 N
Baffle diameter Φ50mm
Baffle thickness Φ5mm
Length of thermocouple >1 meter
Handle diameter Φ30mm
Length of handle 82mm

What is a surface temperature probe?

Surface temperature probes to measure almost any surface. From the handle roller styles to the high-temp foundry style probe, surface thermocouples to meet the most challenging measurement requirements.

Test procedures and operation:

Please refer to the relevant standards.

Take IEC60335-2-6 clause 11.101 as an example:

Temperature rise of the front and side surfaces are measured using the probe of Figure 104. The probe is applied with a force of 4 N ± 1 N to the surface in such a way that best possible contact between the probe and the surface us ensured.

Push the upper surface of the stop face to the force scale line, then 4 N force is achieved.

Inquiry Cart 0