IEC 60598-2-17 Stage Lighting Hanger Weight Bearing Test Machine
Product information:
This device conform to IEC 60598-2-17 clause 17.7.4. and IEC60598-2-23 Clause 7.4 and 7.5.
Technical parameters:
Capacity | 0~1T |
Accuracy level | Level 1 |
Control method | It is controlled by microcomputer |
Display method | Electronic LCD display |
Power unit | kgf, gf, N, kN, lbf |
Stress unit | MPa, kPa, kgf/cm2, lbf/in2 |
Displacement unit | mm, cm, in |
Display resolution | 0. 1N |
Lifting stroke | 600mm |
Platen size | 600*600mm |
Software function | Chinese and english are interchangeable |
Shutdown mode | Overload shutdown, emergency stop button, automatic shutdown of test piece destruction, automatic shutdown of upper and lower limit settings |
Safety equipment | Overload protection, limit element protection device |
Machine power | AC variable frequency motor drive controller |
Computer system | High precision ball screw |
Power supply | AC220V/50Hz |
Machine weight | Around 250KG |
Performance characteristics | The percentage break value can be set, the machine will stop automatically, and 4 different speeds can be selected when enter the menu. 20 results are available, the average of all test results and single results can be viewed. |
Buttons F1~F5 correspond to the functions of the five buttons in the interface respectively.
1 Zero: In the main interface, press the corresponding F1 button to reset the force to zero.
2 Erase: In the main interface, press the corresponding F2 button when the test is stopped to erase the last test result.
3 Up: In the main interface, when the test is stopped, press the corresponding F3 button for a slow rise, and press it again for a fast rise
4 Down: In the main interface, when the test is stopped, press the corresponding F4 button for a slow downward, and press it again for a fast downward.
5 Get-P: In the main interface, press the corresponding F5 button when the test starts:
6 The method to enter the next interface:
First, use F1~F5 to directly enter the next interface.
Second, select the sub-interface in the interface with the selection box, and press ENTER.
Third, press EXIT to exit the sub-interface and return to the previous interface.
7 Press the TEST button in the interface to which the calibration belongs to play a rising role.
Basic operation before use:
1 Please set the test parameters before starting the test, otherwise the system will use the last parameters by default.
2 Please check and save the parameters after setting (it will be automatically saved in some interfaces), and the system will automatically use the saved parameters when the system is turned on next time;
3 Gain 1 is related to the sensitivity of the sensor, and can be matched with the hardware dial switch;
4 The position of the red dial switch has changed, and the hardware zero position should be re-calibrated.