Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Led Testing Equipment /

IEC 60598-2-3 Mast-arm Mounted Luminaries Static Wind Force Test Device

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

IEC 60598-2-3 Mast-arm Mounted Luminaries Static Wind Force Test Device

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN9929
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Customized
Payment Terms :T/T
Supply Ability :15 Sets per Month
Delivery Time :1 Month
Packaging Details :Plywood
Sandbag weight :100kg/Bag
Sandbag quantity :2 bags
Control method :Automatic lifting
Net diamater :Diameter of 1mm
Net material :Polyester fiber
Test weights :Steel load set
Bracket material :SUS304 stainless steel
Applied standard :IEC 60598-2-3
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60598-2-3 Mast-arm Mounted Luminaries Static Wind Force Test Device

Product information:

This machine meets the standards of IEC60598-2-3:2011 clause 3.6.3.1, figure 1 IEC60598-2-5 clause 5.6.5.

It used to detect the static load test of wind resistance for street lamps outdoors.

The working principle is to use a small sandbag to spread evenly on the road lamp under test, or use a net to cover the lamp, and then test the load on the net. This device is suitable for road lampshade wind-force test, equipped with sandbags, test nets, test weights, installation of test bracket, and etc.

Technical parameters:

1. Wind-force simulation sandbag:100kg/Bag, built-in steel ball (adjustable with various weights), two bags (small sandbags according to the test, 20 small bags with various specifications);

2. Control method: automatic lifting console operation;

3. Test net :diameter of 1mm;load weight : 5~500 (KG);material: Polyester fiber; Convenient hook

4. Test weights: Steel load set, chrome plated surface

5. Test bracket: SUS304 stainless steel, can bear 300KG load, equipped with a variety of different street lights, tunnel light fixtures and street lamp holders, can be replaced.

Equipment use steps:
1. Connect the external air source to the air pipe connector on the left side of the access equipment.

2. Fix the lamp to the mounting rod on the left.

3. Cover the lamp with the net, hang the hook on one end of the wire rope to the net.

4. Place the load on the disc on the right, place the corresponding weight of the load in the bag and hook the load to the hook.

Test according to standard:

1. IEC60598-2-3:2011 clause 3.6.3.1 test

Calculate the load applied to the lamp according to the formula.

Set test time 10min.

Press the start button to start the measurement, the disc on the right falls off the load and starts timing, and when the time is up, the disc rises to lift the load.

After the test is completed, there should be no visible damage that compromises safety, the permanent deformation of the attachment should not exceed a slope of 2 cm/m, and there should be no rotation around the attachment.

2. IEC60598-2-5 clause 5.6.5 test

For floodlights used above ground outdoors, a constant, evenly distributed load was applied to the floodlights for 10 minutes using sandbags, which provided a floodlight area of 2.4KN per square meter.

Set test time 10min.

Press the start button to start the measurement, the disc on the right falls off the load and starts timing, and when the time is up, the disc rises to lift the load.

Place the floodlight on a vertical plane, rotate 180° around the attachment point, and repeat the test.

During the test, there shall be no failure or movement in the vicinity of the connection point, and no permanent deformation of more than 1° after any part of the test.