Add to Cart
UL817-2021 Power Cord Abrupt Pull Test Apparatus 6 Stations PLC Control
Standars For Power Cord Abrupt Pull Tester:
The test apparatus is designed and manufactured according to the requirements of UL817-2021 "Standard for safety: Cord Sets and Power-Supply Cords" 11.10.2, 11.10.3, 12.5, 18.2.4 and Figure 12.3 and Figure 12.4 and Figure 18.1.
Technical Parameters For Power Cord Abrupt Pull Tester:
Power supply | Match client's local power supply requirements |
Use environment | Working temperature 0-40℃; Humidity 30%-90% |
Equipment size | About 1000×600×1700 (mm) W×H×D |
Equipment weight | 220kg |
Test station | 6 stations, synchronous |
Electrical control method | Mitsubishi PLC control, 7-inch touch screen operation |
Drive mode | Electric |
Specimen clamping method | Special plug fixture, switchable installation
|
Weight suspension | 1. The weight hook is directly hung on the crimping fixture (Figure 12.3); 2. The weight hook is directly hung on the sample cord (Figure 18.1)
|
Clamp length | 203mm |
Sample tilt angle | 0° and 45°
|
Number of tests | 0-999999 times, can be preset |
Rotation angle | 0°, ±90° or 360° |
Spinning speed | 0-360°/s |
Impact height | 178mm, 254mm, 610mm, can be set |
Load weight | 1. 1.1kg (2.5lb), the weight of the hook, tray and clamping fixture is 907±85g (2 lb±3) 2. 1.4kg (3lb) 3. 15 lbf (67N) 4. 4.5kg (10b) |
Load | 0-12V,40A |
Power on time | 0-9999s can be preset, the default is 120s (2min) |
Impact method | Solenoid release |