IEC 60598-2-23 ELV Light Source Lifting Test Machine LCD Display
Applied Standards For Lifting Test Machine:
Conform to IEC 60598-2-17 clause 17.7.4. and IEC60598-2-23 Clause 7.4 and 7.5.
Technical parameters For Lifting Test Machine:
Capacity | 0~1T |
Accuracy level | Level 1 |
Control method | It is controlled by microcomputer |
Display method | Electronic LCD display |
Power unit | kgf, gf, N, kN, lbf |
Stress unit | MPa, kPa, kgf/cm2, lbf/in2 |
Displacement unit | mm, cm, in |
Display resolution | 0. 1N |
Lifting stroke | 600mm |
Platen size | 600*600mm |
Software function | Chinese and english are interchangeable |
Shutdown mode | Overload shutdown, emergency stop button, automatic shutdown of test piece destruction, automatic shutdown of upper and lower limit settings |
Safety equipment | Overload protection, limit element protection device |
Machine power | AC variable frequency motor drive controller |
Computer system | High precision ball screw |
Power supply | Can be customized |
Machine weight | Around 250KG |
Performance characteristics | The percentage break value can be set, the machine will stop automatically, and 4 different speeds can be selected when enter the menu. 20 results are available, the average of all test results and single results can be viewed. |
Basic Operation Before Use Lifting Test Machine:
1 Please set the test parameters before starting the test, otherwise the system will use the last parameters by default.
2 Please check and save the parameters after setting (it will be automatically saved in some interfaces), and the system will automatically use the saved parameters when the system is turned on next time;
3 Gain 1 is related to the sensitivity of the sensor, and can be matched with the hardware dial switch;
4 The position of the red dial switch has changed, and the hardware zero position should be re-calibrated.
Fault situation | Possible Causes | Method of exclusion |
Turn on the main switch of the instrument, the indicator light at the switch is not on. | Power is not entered Check the rear power socket of the instrument. | Ask an electrician to check the repair power line Check if the power station fuse is broken. |
Press the F3 key and F4 key no action | Button failure Damaged relay Motor speed box damaged | Tighten the screws securing the circuit board Replace relay Replace motor speed box |