Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Switch Life Tester /

Anti - Shock Probe Experiment Device With The Testing Probe IEC 60335-1

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

Anti - Shock Probe Experiment Device With The Testing Probe IEC 60335-1

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN2210-19
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :T/T
Supply Ability :60 Sets Per Month
Delivery Time :5 Days
Packaging Details :Carton
Applied standard :IEC60335-1
Applied clause :Clause 8.1.4
Relative humidity :≤80%
Working temperature :0-40
Working voltage :AC 220V, 50HZ
Electrode output the testing voltage :AC 40-50V
Brand :Sinuo
Warranty :1 year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Anti - Shock Probe Experiment Device Used With The Testing Probe IEC 60335-1

Product Information For Anti - Shock Probe Experiment Device:

This anti-shock probe experiment device is designed and manufactured meet the requirements of the standard of IEC60335-1 Clause 8.1.4, IEC 60065:2014 clause 9.1.1.2, and etc. It is used together with the testing probe for checking whether the probe can contact the live parts of electrical appliance, to verify the protection of persons against access to hazardous parts inside the enclosure.
For the two output electrodes, one of electrodes is connected with the energized part of the electrical appliance and the other electrodes is connected with the input terminal of the probe used. Then turn on the POWER switch of the device, and use the probe to touch the parts that maybe electrified. If the alarm of the equipment sounds, it is proved that the testing part is electrified. Then press the button of reset and cut off the circuit.

Technical Parameters For Anti - Shock Probe Experiment Device:

Applied standard IEC60335-1
Applied clause Clause 8.1.4
Working voltage AC 220V±10%, 50HZ±1%
Electrode output the testing voltage AC40-50V
Working temperature 0-40
Relative humidity: ≤80%
Environment No shaking and no corrosive gas

Notice For Anti - Shock Probe Experiment Device:

1. Check whether connecting wires are conductive.

2. Please do not place two connecting wires on same metal part, so as to avoid the formation of the circuit and error alarm.

3. Be careful of electric shock.

Operation Steps For Anti - Shock Probe Experiment Device:
1. Connect one of the two output electrodes with live part of electrical appliance, connect another with the test finger probe.

2. Then turn on the POWER switch, use the test finger probe to touch other parts of the electrical appliance.

3. If test finger probe touches a live part, electrical contact indicator alarm, buzzer sound, indicating the touched part is a live part, or it is not.

4. Press RESET button to stop alarm and cut off the power supply.

Anti - Shock Probe Experiment Device With The Testing Probe IEC 60335-1