Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Medical Device Testing Equipment /

Manual Control Method Synthetic Blood Penetration Tester For Medical Masks

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

Manual Control Method Synthetic Blood Penetration Tester For Medical Masks

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN122606
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Customized
Payment Terms :L/C, T/T
Supply Ability :20 Sets Per Month
Delivery Time :30 Days
Packaging Details :Plywood
Blood volume :2ml
Control method :Manual
Test medium :Synthetic blood
Time accuracy :0.1s
Pressure value resolution :0.1kPa
Micro-pressure measuring range :0~0.1KPa
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Manual Control Method Synthetic Blood Penetration Tester For Medical Masks

Product overview:

The synthetic blood penetration tester for medical masks is used to measure the jet penetration performance of synthetic blood and other liquid sources in order to evaluate the safety performance of masks. It is mainly used to test the permeability of mask to blood, body fluid, blood causative agent (using Phi-X174), synthetic blood, etc. Suitable for liquid penetration resistance of protective equipment such as masks, gloves, protective clothing, overalls, work clothes, boots, etc. The equipment can output test reports and save test data.

Test method:

The sample of medical mask was supported on the test device, and 2 mL synthetic blood with a surface tension of 0.042 ± 0.002 n / m was sprayed from 300 mm away from the mask under test at a pressure of 16 kPa in the horizontal direction by a catheter with an inner diameter of 0.84 mm. To simulate the mask being splattered with blood from a perforated vessel. Remove the mask within 10 seconds and visually inspect the artificial blood infiltration on the other side of the mask. Respectively with the corresponding liquid injection pressure of 450 cm / s, 550 cm / s, 635 cm / s The medical masks were tested, the test results of each jet velocity were recorded, and the maximum blood pressure corresponding to the quality qualification level limit 4 of the medical masks was given.

Technical parameters:

Basic test principle

Simulate breathing through a vacuum pump, and carry out the pressure difference detection

Main parameters

Test pressure

0~16KPa

Micro-pressure measuring range

0~0.1KPa

Pressure value resolution

0.1kPa

Time accuracy

0.1s

Test medium

Synthetic blood

Control method

Manual

Blood volume

2ml

Scope of application

Surgical mask