Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Electrical Appliance Testing Equipment /

IEC 60335-1 Clause 25.15 Cord Anchorage Pull Force And Torque Tester PLC Control

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

IEC 60335-1 Clause 25.15 Cord Anchorage Pull Force And Torque Tester PLC Control

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN1113L
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :T/T
Supply Ability :20 Sets Per Month
Delivery Time :30 Days
Packaging Details :Plywood Case
Electric control method :PLC+ touch screen
Drive method :Motor and electromagnet drive
Tension method :Horizontal or vertical (optional)
Tensile weight :30N, 40N, 60N, 80N, 100N, and 120N
Rally frequency :1s/time
Torque time :0-9999.9s
Test station :Single station
Power supply :AC220/50Hz
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60335-1 Clause 25.15 Cord Anchorage Pull Force And Torque Tester PLC Control

Product information:

The Cord Anchorage Force and Torque Test Equipment is designed and manufactured according to the standard requirements of IEC60884-1 clause 23.2, IEC60745-1:2006, IEC60335-1 clause 25.15, IEC60598-1 clause 5.2.10.3, IEC60065 clause 16.5 and etc.

The tester is used to conduct two tests of tension and torque at the terminals of appliances (lamps) with power cords, appliances intended to be permanently connected to fixed wiring with flexible cords, and power cords such as household appliances, medical equipment, etc.

The test method is to make a mark at the position of the wire sample 20mm from the fixing device, gently apply the tension 25 times (or the number of times required by other standards) at a rate of 1 time/second, and apply a torque near the exit of the appliance for 1 minute. After the test, the displacement of the marking position of the wire shall not exceed 2mm.

Technical Parameters:

Standard IEC60884-1 Clause 23.2
voltage 220V(AC)50Hz
Electric control method PLC+ touch screen
Drive method Motor and electromagnet drive
Test station Single station, vertical and horizontal cannot be tested at the same time
Sample clamping method Mechanical clamping, clamping point height can be adjustable
Tensile weight 10N: 1 PC, 20N: 3 PC, 30N: 2 PC (The tester can test the tensile weight of 30N, 40N, 60N, 80N, 100N, and 120N)
Tension application method Horizontal or vertical (optional)
Torque weight 4N, 5N, 7.5N, 12.5N, 17.5N, 21.25N (The tester can test the torque weight of 0.08N∙m, 0.1 N∙m, 0.15 N∙m, 0.25 N∙m, 0.35 N∙m, and 0.425 N∙m)
Test times 0~999999 times, can be preset
Rally frequency 1s/time, with tension sensing clip which can verify the tension retention time
Torque time 0-9999.9 seconds, can be preset
Equipment size and weight WDH=650×550×1200mm, approx. 110kg